A Case Study of Energy Saving Using Energy Efficient Motors in a Process Plant
Navpreet Singh1, Navdeep Kaur Brar2, Arvind Dhingra3

1Navpreet Singh, MTech Power System, Department of Electrical Engineering, Baba Banda Singh Bahadur Engineering College, Fatehgarh Sahib (Punjab), India.
2Navdeep Kaur Brar, Asst. Prof., Department of Electrical Engineering, Baba Banda Singh Bahadur Engineering College, Fatehgarh Sahib (Punjab), India.
3Arvind Dhingra, Asst. Prof., Department of Electrical Engineering, Guru Nanak Dev Engineering College, Ludhiana, Punjab, India.

Manuscript received on 15 June 2015 | Revised Manuscript received on 25 June 2015 | Manuscript Published on 30 June 2015 | PP: 90-92 | Volume-4 Issue-5, June 2015 | Retrieval Number: E4044064515/15©BEIESP
Open Access | Editorial and Publishing Policies | Cite | Mendeley | Indexing and Abstracting
© The Authors. Blue Eyes Intelligence Engineering and Sciences Publication (BEIESP). This is an open access article under the CC-BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)

Abstract: Energy conservation is a most talked subject in the today’s world because energy consumption in various industries in India is a great issue. The standard induction motors in a process plant consume large amount of energy due to low efficiency. To save energy consumption in a process plant, the use of energy efficient motors are chosen over standard induction motor. Energy efficient motors have better efficiency and power factor than standard induction motors. The use of energy efficient motors reduces energy consumption of the plant. The plant under study has 40 motors of different ratings. The work presented in the paper examines the usage of extra energy in various standard induction motors in a process plant and encourage the use of energy efficient motors over standard induction motors. For this objective, a comparison of standard induction motors with energy efficient motors based on efficiency, (kW) motor input power, (kVA) apparent power, power factor, energy consumed (kWh) according to running hours in a year and current. The payback period for energy efficient motors has also been calculated. In the end the study found that replacing standard motors with energy efficient motors is better and overall plant motor load also reduces.
Keywords: Standard Induction Motor, Energy Efficient Motor, Efficiency, Kilowatt, Power Factor, Energy Conservation

Scope of the Article: Renewable Energy Technology